کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4295536 1612323 2007 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A Phase 3, Randomized, Double-Blind Comparative Study of the Efficacy and Safety of Topical Recombinant Human Thrombin and Bovine Thrombin in Surgical Hemostasis
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی عمل جراحی
پیش نمایش صفحه اول مقاله
A Phase 3, Randomized, Double-Blind Comparative Study of the Efficacy and Safety of Topical Recombinant Human Thrombin and Bovine Thrombin in Surgical Hemostasis
چکیده انگلیسی

BackgroundPlasma-derived bovine thrombin is used as a topical agent to improve surgical hemostasis, but development of antibodies to bovine hemostatic proteins has been associated with increased bleeding and thrombotic complications. Recombinant human thrombin could reduce the risk of these complications.Study DesignThe objective of this randomized, double-blind, comparative trial was to compare the efficacy, safety, and antigenicity of recombinant human thrombin (rhThrombin) and bovine thrombin as adjuncts to hemostasis in liver resection, spine, peripheral arterial bypass, and dialysis access surgery. Blinded study drug was applied topically to bleeding sites with an absorbable gelatin sponge. The primary efficacy end point was time to hemostasis, summarized as the incidence of hemostasis within 10 minutes. Safety analyses were conducted for 1 month after operation, and the development of antibodies to rhThrombin or to the bovine product was evaluated.ResultsFour hundred one patients completed this trial. Hemostasis was achieved at the time-to-hemostasis evaluation site within 10 minutes in 95% of patients in each treatment group. Overall complications, including operative mortality, adverse events, and laboratory abnormalities, were similar between groups. Forty-three (21.5%) patients receiving bovine thrombin developed antibodies to the product; three patients (1.5%; p < 0.0001) in the rhThrombin group developed antibodies to rhThrombin. None of the three patients who developed antirhThrombin antibodies had abnormal coagulation laboratory results or bleeding, thromboembolic, or hypersensitivity events.ConclusionsResults of this trial suggest that rhThrombin has comparable efficacy, a similar safety profile, and is considerably less immunogenic than bovine thrombin when used for surgical hemostasis.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Surgeons - Volume 205, Issue 2, August 2007, Pages 256–265
نویسندگان
, , , , , , , ,