کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4299153 1288383 2016 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Ultrasonographic measurements of the inferior vena cava variation as a predictor of fluid responsiveness in patients undergoing anesthesia for surgery
ترجمه فارسی عنوان
اندازه گیری های سونوگرافی از تغییرات وحشی کمر وارونه به عنوان یک پیش بینی کننده پاسخ مایع در بیماران تحت بیهوشی برای جراحی
کلمات کلیدی
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی عمل جراحی
چکیده انگلیسی

BackgroundBoth hypovolemia and hypervolemia are connected with increased morbidity and mortality in the treatment and prognosis of patients. An accurate assessment of volume state allows the optimization of organ perfusion and oxygen supply. Recently, ultrasonography has been used to detect hypovolemia in critically ill patients and perioperative patients. The objective of our study was to assess the correlation between inferior vena cava (IVC) variation obtained with ultrasound and stroke volume variation (SVV) measured by the Vigileo/FloTrac monitor, as fluid responsiveness indicators, in patients undergoing anesthesia for surgery.MethodsForty patients (American Society of Anesthesiologists grades I and II) scheduled for elective gastrointestinal surgery were enrolled in our study. After anesthesia induction, 6% hydroxyethyl starch solution was administered to patients as an intravenous (IV) fluid. The IVC diameters were measured with ultrasonography. SVV and stroke volume index (SVI) were obtained from the Vigileo monitor. All data were collected both before and after fluid challenge.ResultsForty patients underwent IVC sonographic measurements and SVV calculation. After fluid challenge, mean arterial pressure, central venous pressure, SVI, and IVC diameters increased significantly, whereas SVV decreased markedly. The correlation coefficient between the increase in SVI and the baseline of IVC variation after an IV fluid was 0.710, and receiver operating characteristic (ROC) curve was 0.85. The correlation coefficient between the increase in SVI and the baseline of SVV was 0.803 with an ROC curve of 0.93. Central venous pressure had no significant correlation with SVI.ConclusionsOur data show that IVC variation and SVV proved to be reliable predictors of fluid responsiveness in patients undergoing anesthesia for surgery with mechanical ventilation.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Surgical Research - Volume 204, Issue 1, July 2016, Pages 118–122
نویسندگان
, , , , , ,