Crew's health and productivity is strongly affected by cabins’ thermal environment. This paper focuses on the numerical simulation of the indoor thermal environment in air-conditioned vessel cabins. The original airconditioning system of the cabin was analyzed. Three modified air-conditioning systems with different air-supply outlet locations and under-supply air-conditioning system were put forward for optimization. Air temperature, air velocity and PMV distribution were discussed under Airpak simulation. The results show that under-supply airconditioning system has good performance with little eddies and can contribute to energy saving. Indoor air temperature with under-supply air-conditioning system was 2∼4 lower than that °C with original air-conditioning system, leading to lower predicted mean vote (PMV).
Journal: Procedia Environmental Sciences - Volume 11, Part C, 2011, Pages 1055-1063