کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4420668 1618983 2012 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Automated high-throughput Vibrio fischeri assay for (eco)toxicity screening: Application to ionic liquids
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم محیط زیست شیمی زیست محیطی
پیش نمایش صفحه اول مقاله
Automated high-throughput Vibrio fischeri assay for (eco)toxicity screening: Application to ionic liquids
چکیده انگلیسی

An automated high-throughput Vibrio fischeri assay was developed and further applied to the evaluation of ionic liquids (ILs) (eco)toxicity. The assay was based on the reduction of bacterial bioluminescence in the presence of test compounds and the results were presented as EC50. The assays were performed with eight commercially available ILs with distinct cationic head groups, alkyl side chains and anions. EC50 values between 6.5 and 691.9 mmol L−1 were obtained for the tested ILs, being hmim [Cl] the most toxic and bmim [Cl] the less toxic ones, confirming the influence of the different structural elements. Moreover, all the tested ILs exhibited a (eco)toxicity lower than Cu(II), used as a positive control during the optimization and analysis steps. The automated assay assured the precise control of the contact time between V. fischeri and test compound by means of a simple protocol that guaranteed adequate aspiration and handling of the solutions as well as the precise implementation of a computer controlled stop period. Furthermore, a significant reduction of the assay costs was achieved through automation mainly by a drastic reduction of the volume of bacterial suspension and test compound. The methodology was validated by comparison with a microplate assay; it was stated that the results, obtained after a 3 min contact time, changed proportionally relatively to Cu(II) in both assays. This confirmed the applicability of the methodology as an (eco)toxicity screening assay, with reduction of time and increase of robustness and repeatability (n=10; rsd<1.1%). It is expected that due to its simplicity and reduced cost the developed assay can be integrated in the early stage of development of new compounds as a rapid screening test.

Graphical AbstractFigure optionsDownload as PowerPoint slideHighlights
► The Vibrio fischeri assay was implemented in a SIA system.
► A highly precise and robust assay was obtained.
► The automated assay was applied to the evaluation of ILs (eco)toxicity.
► The assay was validated by comparison with a microplate format.
► (Eco)toxicity data was related with structural particularities of the ILs.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Ecotoxicology and Environmental Safety - Volume 80, 1 June 2012, Pages 97–102
نویسندگان
, , , ,