کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4438716 1620415 2012 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Assessment of indoor PM2.5 in different residential environments
موضوعات مرتبط
مهندسی و علوم پایه علوم زمین و سیارات علم هواشناسی
پیش نمایش صفحه اول مقاله
Assessment of indoor PM2.5 in different residential environments
چکیده انگلیسی

The indoor air quality (IAQ) as assessed by PM2.5 (particulate matter with an aerodynamic diameter of less than 2.5 μm) was measured at indoor settings in various residential houses which were located in different local environments across Kuwait. The indoor house settings included kitchen, living room, and bedrooms. Samples were collected from houses over 24 h. PM2.5 was estimated using a Dust-Trak personal sampler. Results were analyzed and compared with the US Environmental Protection Agencies (EPA) and World Health Organization (WHO) standards and guidelines. The results demonstrated that kitchens have the highest PM2.5 concentration probably due to cooking activities; the bedroom has the lowest PM2.5 concentration. The study shows that Kuwait indoor residential pollution is among the worst in comparison with other countries.


► Measured PM2.5 at different locations in house at various residential environments.
► The kitchen has the highest PM2.5 concentration due to cooking activities.
► The bedroom has the lowest PM2.5 concentration.
► The PM2.5 concentration in the residential living room in Kuwait is higher than EPA.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Atmospheric Environment - Volume 56, September 2012, Pages 65–68
نویسندگان
, , ,