عنوان انگلیسی مقاله ISI
Performance evaluation of modified Semi-continuous Elements in Aerosol Sampler-III
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه علوم زمین و سیارات علم هواشناسی
پیش نمایش صفحه اول مقاله
Performance evaluation of modified Semi-continuous Elements in Aerosol Sampler-III
چکیده انگلیسی

A field study was conducted to evaluate the performance of a Semi-continuous Elements in Aerosol Sampler-III (SEAS-III), designed to collect ambient PM2.5 aerosol samples at a time resolution of 30 min for elemental concentration measurements. Two identical but modified SEAS-III samplers were operated for four continuous weeks in Dearborn, MI, during July–August 2007. A total of 2308 samples were collected from the two samplers. Sampling completeness from the primary and duplicate samplers was 90% and 84%, respectively. All of the collected samples were analyzed for dilute acid-extractable trace metal concentrations using HR-ICPMS.A total of 878 collection time-matched sample pairs were available to evaluate whole-system uncertainty from collocated concentration measurements. The collocated precision for the 27 studied elements (Al, As, Ba, Ca, Cd, Ce, Cs, Cu, Fe, Ge, K, La, Mg, Mn, Mo, Na, P, Pb, Rb, S, Sb, Se, Sn, Sr, Ti, V, and Zn) varied between 9% and 40%. Twenty elements showed precision better than 25%. Uncertainty estimates from propagation of errors compared well with the whole-system uncertainty values for all minor aerosol elements studied. SEAS-III measurements of As, Cd, Ge, K, La, Mn, Mo, Na, Rb, Se, Sb, Sr, Ti, V, and Zn correlated well (r > 0.8) with a FRM equivalent PM2.5 integrated filter sampling method. Based on these measurements, collection efficiency of SEAS-III was estimated to be 87 ± 16%. Solubility of particles in the collection medium (water) was identified as a possible reason for low recovery of Al, Fe, Pb, Sb, and Sn.


► SEAS-III offers trace element concentrations at sub-hourly resolution.
► Two modified SEAS-III were collocated and results compared against FRM data.
► Most elements in primary particle emissions compared well.
► Precision and accuracy of elements from SEAS-III are reported for the first time.
► Collection efficiency of SEAS-III was estimated to be 87 ± 16%.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Atmospheric Environment - Volume 45, Issue 37, December 2011, Pages 6751–6759