کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
443922 692816 2014 20 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Group-wise construction of reduced models for understanding and characterization of pulmonary blood flows from medical images
ترجمه فارسی عنوان
ساخت مدل های کاهش یافته ای برای شناخت و مشخص کردن جریان خون ریوی از تصاویر پزشکی، ساختار گروهی است
موضوعات مرتبط
مهندسی و علوم پایه مهندسی کامپیوتر گرافیک کامپیوتری و طراحی به کمک کامپیوتر
چکیده انگلیسی


• Patient-specific pulmonary artery geometries are reconstructed from MR.
• An unbiased atlas is computed for 17 Tetralogy of Fallot patients.
• Individual model order reduction is developed for fast blood flow simulations.
• Robustness to changes of condition (rest/exercise) and degrees of regurgitation.

3D computational fluid dynamics (CFD) in patient-specific geometries provides complementary insights to clinical imaging, to better understand how heart disease, and the side effects of treating heart disease, affect and are affected by hemodynamics. This information can be useful in treatment planning for designing artificial devices that are subject to stress and pressure from blood flow. Yet, these simulations remain relatively costly within a clinical context. The aim of this work is to reduce the complexity of patient-specific simulations by combining image analysis, computational fluid dynamics and model order reduction techniques. The proposed method makes use of a reference geometry estimated as an average of the population, within an efficient statistical framework based on the currents representation of shapes. Snapshots of blood flow simulations performed in the reference geometry are used to build a POD (Proper Orthogonal Decomposition) basis, which can then be mapped on new patients to perform reduced order blood flow simulations with patient specific boundary conditions. This approach is applied to a data-set of 17 tetralogy of Fallot patients to simulate blood flow through the pulmonary artery under normal (healthy or synthetic valves with almost no backflow) and pathological (leaky or absent valve with backflow) conditions to better understand the impact of regurgitated blood on pressure and velocity at the outflow tracts. The model reduction approach is further tested by performing patient simulations under exercise and varying degrees of pathophysiological conditions based on reduction of reference solutions (rest and medium backflow conditions respectively).

Figure optionsDownload high-quality image (168 K)Download as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Medical Image Analysis - Volume 18, Issue 1, January 2014, Pages 63–82
نویسندگان
, , , , , , , , , ,