کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
4442296 | 1311145 | 2009 | 8 صفحه PDF | دانلود رایگان |
Determination of polycyclic aromatic hydrocarbons (PAHs) from chemical analysis of the diesel particulate matter (DPM) requires considerable sampling expertise and is often time-consuming because sample preparation demands strict extraction procedures due to the complex nature of the DPM matrix. In this study, a method to measure the emissions of the 16-U.S. Environmental Protection Agency (EPA) priority PAHs adsorbed in diesel particles has been developed. This method involves the capture of the DPM in glass microfibre filters, thermal extraction of the compounds from the particulate matrix in a thermogravimetric analyzer (TGA), determination of the concentration by means of a solid phase micro-extraction (SPME) fibre and subsequent analysis using a gas chromatograph coupled to a mass spectrometer (GC/MS). Analyses of a fully characterised DPM prepared by the National Institute of Standards and Technology, NIST (SRM 1650b), were performed and calculated errors showed that the method is capable of giving reliable quantitative data. Additionally, DPM collected from a diesel engine was analyzed and the results showed the high method sensitivity to the engine operating conditions.
Journal: Atmospheric Environment - Volume 43, Issue 3, January 2009, Pages 655–662