کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4519311 1322829 2009 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Evaluation of shelf-life of fresh-cut pineapple using FT-NIR and FT-IR spectroscopy
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم کشاورزی و بیولوژیک علوم زراعت و اصلاح نباتات
پیش نمایش صفحه اول مقاله
Evaluation of shelf-life of fresh-cut pineapple using FT-NIR and FT-IR spectroscopy
چکیده انگلیسی

The aim of this work was to investigate the loss of freshness of fresh-cut pineapple samples stored at different temperatures using non-destructive spectroscopic methods. Three lots of fresh cut pineapples (Ananas comosus L. cv. Golden Ripe, from Costa Rica), packaged in PVC trays (250 g) were analyzed during storage at three different temperatures (5.3, 8.6 and 15.8 °C). Loss of quality of these fruit was evaluated by chemical and microbiological parameters and using NIR and MIR spectroscopy. The FT-NIR spectra were acquired in reflectance mode directly on the slice of fresh-cut pineapple, over the range 12,500–3900 cm−1, while FT-IR spectra were collected over the range 4000–700 cm−1 using an horizontal ATR cell. Some chemical and microbiological parameters were also measured. Principal component analysis (PCA) was applied to the second derivative of the spectra to uncover molecular modifications occurring over the storage time. A clear discrimination between “fresh” and “old” samples was obtained and a stability time corresponding to the time of the initial loss of freshness was defined at each temperature. The stability times revealed by NIR spectroscopy were in good accordance with those evaluated by MIR. At each temperature the stability times (i.e. the initial loss of freshness times) defined by spectroscopic techniques (4–5 d at 5.3 °C, 3–4 d at 8.6 °C and 1 d at 15.8 °C) were associated with a mesophilic bacteria count ranging between 105 and 106 CFU g−1 and lower than the maximum limit for mesophilic bacteria (<5 × 107 CFU g−1) given by French hygienic regulations at consumption.These results show that NIR and MIR spectroscopy could support conventional techniques (chemical and microbiological analysis) in studying shelf-life of fresh-cut fruit. In particular these techniques define the initial loss of freshness time, indicating a product which rapidly will be no longer acceptable if stored beyond that time. The main advantage of using IR spectroscopic techniques is to rapidly draw a profile of the product related to its change in quality.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Postharvest Biology and Technology - Volume 54, Issue 2, November 2009, Pages 87–92
نویسندگان
, , , , , ,