کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4919267 1428950 2017 29 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
An infrared thermography passive approach to assess the effect of leakage points in buildings
ترجمه فارسی عنوان
یک روش منفعل ترموگرافی مادون قرمز برای ارزیابی اثر نشت در ساختمان ها
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
چکیده انگلیسی
It was possible to conclude that the window frame had a larger contribution to the air flow rate than the roller shutter handle (109.4 m3/h and 21.7 m3/h, at a pressure difference of 50 Pa). Qualitative analysis of the thermal images indicated that a colder area near the leakage point can be detected and that it grows with the increase of the pressure difference. The quantitative approach showed that a stabilization of the surface temperature close to the value of the outdoor temperature occurred and the relative differences are around 15% both for the window frame and the roller shutter handle. It also showed that, in most cases, the first pressure step (ΔP = 25 Pa) is responsible for about 60% of the differences in the superficial temperature. A good correlation was found between the proposed Pressurization Thermal Index and the temperature gradient between the exterior air temperature and the initial superficial temperature (ranging from 0.74 to 0.82).
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy and Buildings - Volume 140, 1 April 2017, Pages 224-235
نویسندگان
, , ,