کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4921126 1429335 2017 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A Pb-TLD spectrometer to measure high energy photons in z-pinch experiments on the primary test stand
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
A Pb-TLD spectrometer to measure high energy photons in z-pinch experiments on the primary test stand
چکیده انگلیسی
A Pb-TLD spectrometer has been developed based on attenuation techniques to measure high energy photons in wire-array z-pinch experiments on the primary test stand (PTS). It is composed of a stack of 18 lead filters interspersed with 19 thermoluminescent dosimeters (TLD). A shield is constructed for the spectrometer and scattered radiation is reduced to less than 5% by the shield. Response functions of the spectrometer are calculated by MCNP5 for 0-2 MeV photons. Based on response functions and 19 dose data measured in experiments, energy spectra of high energy photons on PTS has been firstly obtained by unfolding programs developed with MATLAB code using iterative least square fit. Results show that energy peak locates within 200 keV and 300 keV, and the fluence decreases to background level at energy higher than 1.3 MeV.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Fusion Engineering and Design - Volume 118, May 2017, Pages 1-4
نویسندگان
, , , , , , , ,