												EMBICOLLANVISAMPVPTCP. aeruginosaMPNNTUCFUSODISPCA - PCASafe water - آب سالمEscherichia coli - اشریشیا کُلیUltraviolet - اشعه فرابنفشE. coli - باکتری E. coliintensive care unit - بخش مراقبتهای ویژهICU - بخش مراقبتهای ویژهmost probable number - بیشترین تعداد احتمالیCrest - تاجPseudomonas aeruginosa - سودوموناس آئروژینوزاPlate Count Agar - شمارش آگارSolar disinfection - ضد عفونی خورشیدیParabolic trough concentrator - غلظت پابالیکیThermal inactivation - غیر فعال کردن حرارتیnephelometric turbidity unit - واحد کدورت غیرفلومتریکcolony-forming units - واحدهای تشکیل دهنده کلنیPathogens - پاتوژن
												موضوعات مرتبط
												
													مهندسی و علوم پایه
													مهندسی انرژی
													انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
												
											چکیده انگلیسی
												The ingestion of contaminated water is a major cause of disease and death in developing countries. The decontamination of water can be achieved by different methods of treatment. However, solar pasteurization shows promise for inactivating microorganisms at different temperatures. In this work, a solar pasteurization system operating by automated batches has been both designed and tested. A flat solar collector with 2 m2 of aperture, a heat exchanger, two solenoid valves, two thermoresistances and an electronic control were used to perform water treatment in different preprogrammed “set points”: 3600 s at 55 °C; 2700 s at 60 °C; 1800 s at 65 °C; 900 s at 75 °C and 15 s at 85 °C. The system showed advantages over other existing pasteurizers in literature when it comes to the possibility of performing treatment in several temperatures, the complete segregation between water masses and the ability of controlling water residence time in the solar collector. The use of heat exchanger has great importance since it implies increased productivity of about 110% and significant reduction of solar radiation cutting level at about 6.6 MJ/m2 day. The experimental data also showed that it was possible to achieve productivity of 80 L of treated water in a day of clear sky. Furthermore, the pasteurizer remained stable for elimination efficiency of the tested microorganisms, considering the 85 °C treatment temperature for 15 s. Bacteriological analysis after treatment showed absence of total coliforms and Escherichia coli, MPN <1.1 Pseudomonas aeruginosa and 98.7% average reduction of heterotrophic bacteria at different levels of water sample contamination.
											ناشر
												Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Renewable Energy - Volume 105, May 2017, Pages 257-269
											Journal: Renewable Energy - Volume 105, May 2017, Pages 257-269
نویسندگان
												Gustavo Carielo, GlÃcia Calazans, Glaucia Lima, Chigueru Tiba, 
											