کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4999472 1368350 2017 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Investigation using localised SVET into protection at defects in epoxy coated mild steel under intermittent cathodic protection simulating inter-tidal and splash zones
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی تکنولوژی و شیمی فرآیندی
پیش نمایش صفحه اول مقاله
Investigation using localised SVET into protection at defects in epoxy coated mild steel under intermittent cathodic protection simulating inter-tidal and splash zones
چکیده انگلیسی
Cathodic protection (CP) should not work in the splash and intertidal zones because there is no persistent electrolyte pathway for the protection current to flow. Nonetheless, there is anecdotal evidence that CP can influence the corrosion processes in these challenging regions of a structure and this is at least possible, since thin electrolyte pathways can persist for some time on intermittently wetted surfaces even after the bulk fluid has receded. Here we demonstrate that the Scanning Vibrating Electrode Technique (SVET) may be used to measure local current at coating defects in thin electrolyte layers, and can probe the influence of cathodic protection on the local currents at the defect site. We confirm that cathodic protection is effective in thin electrolyte layers and, significantly, that calcareous films form under these conditions in seawater. Such films are found to be persistent in the absence of cathodic polarisation and provide significant local inhibition of current flow at the defect site.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Progress in Organic Coatings - Volume 102, Part A, January 2017, Pages 66-70