کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
5363708 | 1388305 | 2010 | 4 صفحه PDF | دانلود رایگان |
For the microfluidic chip, the surface roughness of the chamber sidewall is an important parameter in estimating its quality. In this work, the chambers of the polymethyl methacrylate (PMMA)-based microfluidic chip were fabricated by CO2 laser cutting, and then the surface roughness of the sections cut using different laser parameters and ambient temperature was studied by a non-contact 3D surface profiler. Our observation shows that the surface roughness results primarily from the residues on the laser-cut edge, which are produced by the bubbles bursting. To reduce the surface roughness of the cut section, a new approach is proposed, that is preheating the PMMA sheet to a suitable ambient temperature during laser processing. The results indicate that at a preheat temperature of 70-90 °C, the surface roughness resulting from the cut would be reduced. In our experiment, the best result was that the arithmetical mean roughness is Ra = 100.86 nm when the PMMA sheet was heated to 85 °C.
Journal: Applied Surface Science - Volume 256, Issue 6, 1 January 2010, Pages 1675-1678