کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5434337 1509141 2017 13 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A strategy to promote the electroactive platform adopting poly(o-anisidine)-silver nanocomposites probed for the voltammetric detection of NADH and dopamine
موضوعات مرتبط
مهندسی و علوم پایه مهندسی مواد بیومتریال
پیش نمایش صفحه اول مقاله
A strategy to promote the electroactive platform adopting poly(o-anisidine)-silver nanocomposites probed for the voltammetric detection of NADH and dopamine
چکیده انگلیسی


- POA-Ag nanocomposites were used for the simultaneous determination of NADH and DA.
- The nanocomposites were characterized by XRD, Raman, XPS and HRTEM.
- The important electrochemical parameters of NADH and DA were evaluated.
- The practicality of the proposed sensor has been determined.

A study on the voltammetric detection of NADH (β-nicotinamide adenine dinucleotide), Dopamine (DA) and their simultaneous determination is presented in this work. The electrochemical sensor was fabricated with the hybrid nanocomposites of poly(o-anisidine) and silver nanoparticles prepared by simple and cost-effective insitu chemical oxidative polymerization technique. The nanocomposites were synthesized with different (w/w) ratios of o-anisidine and silver by increasing the amount of o-anisidine in each, by keeping silver at a fixed quantity. The XRD patterns revealed the semi-crystalline nature of poly(o-anisidine) and the face centered cubic structure of silver. The presence of silver in its metallic state and the formation of nanocomposite were established by XPS analysis. Raman studies suggested the presence of site-selective interaction between poly(o-anisidine) and silver. HRTEM studies revealed the formation of polymer matrix type nanocomposite with the embedment of silver nanoparticles. The sensing performance of the materials were studied via cyclic voltammetry, differential pulse voltammetry and chronoamperometry techniques. Fabricated sensor with 3:1 (w/w) ratio of poly(o-anisidine) and silver exhibited good catalytic activity towards the detection of NADH and DA in terms of potential and current response, when compared to others. Several important electrochemical parameters regulating the performance of the sensor have been evaluated. Under the optimum condition, differential pulse voltammetry method exhibited the linear response in the range of 0.03 to 900 μM and 5 to 270 μM with a low detection limit of 0.006 μM and 0.052 μM for NADH and DA, respectively. The modified electrodes exhibited good sensitivity, stability, reproducibility and selectivity with well-separated oxidation peaks for NADH and DA in the simultaneous determination of their binary mixture. The analytical performance of the nanocomposite as an electrochemical sensor was also established for the determination of NADH in human urine and water samples and DA in pharmaceutical dopamine injections with satisfactory coverage.

321

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Materials Science and Engineering: C - Volume 80, 1 November 2017, Pages 425-437
نویسندگان
, , , ,