کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5493422 1526275 2017 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Performance of a prototype active veto system using liquid scintillator for a dark matter search experiment
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم ابزار دقیق
پیش نمایش صفحه اول مقاله
Performance of a prototype active veto system using liquid scintillator for a dark matter search experiment
چکیده انگلیسی
We report the performance of an active veto system using a liquid scintillator with NaI(Tl) crystals for use in a dark matter search experiment. When a NaI(Tl) crystal is immersed in the prototype detector, the detector tags 48% of the internal 40K background in the 0-10 keV energy region. We also determined the tagging efficiency for events at 6-20 keV as 26.5±1.7% of the total events, which corresponds to 0.76±0.04 events/keV/kg/day. According to a simulation, approximately 60% of the background events from U, Th, and K radioisotopes in photomultiplier tubes are tagged at energies of 0-10 keV. Full shielding with a 40-cm-thick liquid scintillator can increase the tagging efficiency for both the internal 40K and external background to approximately 80%.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 851, 11 April 2017, Pages 103-107
نویسندگان
, , , , , , , , , ,