Simple and rapid quantification of serotonin transporter binding using [11C]DASB bolus plus constant infusion
موضوعات مرتبط
علوم زیستی و بیوفناوری علم عصب شناسی علوم اعصاب شناختی
پیش نمایش صفحه اول مقاله
Simple and rapid quantification of serotonin transporter binding using [11C]DASB bolus plus constant infusion
چکیده انگلیسی


- SERT binding potentials in 15 min of scan time using [11C]DASB bolus + infusion.
- Reliability was compared to gold-standard tracer bolus and arterial blood sampling.
- High reliability of BP in thalamus and striatal regions with ICCs 0.73-0.90.
- A protocol for SERT quantification in up to 3 patients with one radiosynthesis.

IntroductionIn-vivo quantification of serotonin transporters (SERT) in human brain has been a mainstay of molecular imaging in the field of neuropsychiatric disorders and helped to explore the underpinnings of several medical conditions, therapeutic and environmental influences. The emergence of PET/MR hybrid systems and the heterogeneity of SERT binding call for the development of efficient methods making the investigation of larger or vulnerable populations with limited scanner time and simultaneous changes in molecular and functional measures possible. We propose [11C]DASB bolus plus constant infusion for these applications and validate it against standard analyses of dynamic PET data.Methods[11C]DASB bolus/infusion optimization was performed on data acquired after [11C]DASB bolus in 8 healthy subjects. Subsequently, 16 subjects underwent one scan using [11C]DASB bolus plus constant infusion with Kbol 160-179 min and one scan after [11C]DASB bolus for inter-method reliability analysis. Arterial blood sampling and metabolite analysis were performed for all scans. Distribution volumes (VT) were obtained using Logan plots for bolus scans and ratios between tissue and plasma parent activity for bolus plus infusion scans for different time spans of the scan (VT-70 for 60-70 min after start of tracer infusion, VT-90 for 75-90 min, VT-120 for 100-120 min) in 9 subjects. Omitting blood data, binding potentials (BPND) obtained using multilinear reference tissue modeling (MRTM2) and cerebellar gray matter as reference region were compared in 11 subjects.ResultsA Kbol of 160 min was observed to be optimal for rapid equilibration in thalamus and striatum. VT-70 showed good intraclass correlation coefficients (ICCs) of 0.61-0.70 for thalamus, striatal regions and olfactory cortex with bias ≤5.1% compared to bolus scans. ICCs increased to 0.72-0.78 for VT-90 and 0.77-0.93 for VT-120 in these regions. BPND-90 had negligible bias ≤2.5%, low variability ≤7.9% and ICCs of 0.74-0.87; BPND-120 had ICCs of 0.73-0.90. Low-binding cortical regions and cerebellar gray matter showed a positive bias of ~8% and ICCs 0.57-0.68 at VT-90. Cortical BPND suffered from high variability and bias, best results were obtained for olfactory cortex and anterior cingulate cortex with ICC=0.74-0.75 for BPND-90. High-density regions amygdala and midbrain had a negative bias of −5.5% and −22.5% at VT-90 with ICC 0.70 and 0.63, respectively.ConclusionsWe have optimized the equilibrium method with [11C]DASB bolus plus constant infusion and demonstrated good inter-method reliability with accepted standard methods and for SERT quantification using both VT and BPND in a range of different brain regions. With as little as 10-15 min of scanning valid estimates of SERT VT and BPND in thalamus, amygdala, striatal and high-binding cortical regions could be obtained. Blood sampling seems vital for valid quantification of SERT in low-binding cortical regions. These methods allow the investigation of up to three subjects with a single radiosynthesis.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: NeuroImage - Volume 149, 1 April 2017, Pages 23-32
نویسندگان
, , , , , , , , , , , , , , , , , ,