کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5652459 1588889 2017 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Management of displaced inferior patellar pole fractures with modified tension band technique combined with cable cerclage using Cable Grip System
ترجمه فارسی عنوان
مدیریت شکستگی قطبهای پاتلا در ناحیه جابجایی با تکنیک باند اصلاح شده همراه با کابل سرکلاژ با استفاده از سیستم دستگیره کابل
کلمات کلیدی
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی طب اورژانس
چکیده انگلیسی

IntroductionWe present a modified tension band technique combined with cable cerclage using Cable Grip System for the treatment of displaced inferior patellar pole fractures and report the knee functional outcome.Patients and methodsThe patients who had had operative treatment of a displaced inferior patellar pole fracture (AO/OTA 34-A1) between December 2013 and December 2015 were studied retrospectively. Eleven consecutive patients had had open reduction and internal fixation with the modified technique using Cable Grip System, of whom, five males and six females with an average age of 60.9 years (range, 29-81 years). All fractures occurred from direct fall onto the knee. The average time from injury to surgery was 6.1 days (range, 2-12 days). The range of motion (ROM) was measured in degrees by goniometry at postoperative intervals of 1, 2, 4, 12, and 48 weeks; Knee function was evaluated using the Rasmussen scores at final follow-up.ResultsNo patients had nonunion, loss of reduction, migration of wire, irritation from the implant and fixation breakage during the follow-up period. Recovery of ROM was achieved at 12 weeks, with the average ROM at 1 week was 72° (range, 65°-78°), 86.4° (range, 78°-92°) at 2 weeks, 115.5° (range, 103°-122°) at 4 weeks, 129.6° (range, 122°-133°) at 12 weeks, 134.5° (range, 129°-139°) at 48 weeks after the operation. Concerning the knee function outcome assessment, all patients showed excellent results at final follow-up. The average Rasmussen scores was 27.9 out of 30 (range, 27-29).ConclusionsThe modified tension band technique combined with cable cerclage using Cable Grip System for displaced inferior patellar pole fractures can provide stable fixation with excellent results in knee function, allows for immediate mobilization and early weight-bearing, which is a simple and valuable technique in routine clinical practice.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Injury - Volume 48, Issue 10, October 2017, Pages 2348-2353
نویسندگان
, , , ,