کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5668414 1407900 2017 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Evaluation of a modified cleaning procedure in the prevention of carbapenem-resistant Acinetobacter baumannii clonal spread in a burn intensive care unit using a high-sensitivity luminometer
موضوعات مرتبط
علوم زیستی و بیوفناوری ایمنی شناسی و میکروب شناسی میکروبیولوژی و بیوتکنولوژی کاربردی
پیش نمایش صفحه اول مقاله
Evaluation of a modified cleaning procedure in the prevention of carbapenem-resistant Acinetobacter baumannii clonal spread in a burn intensive care unit using a high-sensitivity luminometer
چکیده انگلیسی

SummaryBackgroundEnhanced environmental cleaning practices are among the most accepted measures for controlling the spread of carbapenem-resistant Acinetobacter baumannii (CR-Ab).AimTo evaluate the impact of heightened cleaning on an ongoing CR-Ab outbreak in a burn intensive care unit (BICU) of an Italian teaching hospital, where chlorhexidine-60% isopropyl alcohol was applied as a complementary disinfectant on high-touch surfaces.MethodsCompliance with the microbial limit proposed for the BICU by AFNOR-NF-S90-351 (20 colony-forming units/100cm2) was assessed by plate count, and compared with the results obtained with intracellular adenosine triphosphate (ATP) detection. Genotyping was performed using pulsed-field gel electrophoresis.FindingsDuring the standard cleaning regimen, three out of 23 samples (13%) gave results over the AFNOR limit and five (21.7%) showed unacceptable ATP levels with 100 relative light units/100 cm2 as the benchmark limit (sensibility 86.4%, specificity 92.2%). Following improvement of the cleaning procedure, only two samples out of 50 (4%) did not satisfy the microbiological criteria and seven (14%) exceeded the ATP limit. In a successive phase, eight of 30 samples collected showed unacceptable results (27%).ConclusionsAdding chlorhexidine-60% isopropyl alcohol as complementary disinfectant proved to be effective for reducing environmental microbial contamination, ATP levels and CR-Ab infection/colonization in patients admitted to the BICU. Real-time monitoring by ATP assay was useful for managing the cleaning schedule and reducing hospital infections, although the calculated values must be interpreted as cleanliness indicators rather than risk indicators.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Hospital Infection - Volume 95, Issue 1, January 2017, Pages 46-52