کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
569929 876697 2009 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Selection of the implant thread pitch for optimal biomechanical properties: A three-dimensional finite element analysis
موضوعات مرتبط
مهندسی و علوم پایه مهندسی کامپیوتر نرم افزار
پیش نمایش صفحه اول مقاله
Selection of the implant thread pitch for optimal biomechanical properties: A three-dimensional finite element analysis
چکیده انگلیسی

In this paper, effects of the implant thread pitch on the maximum Von Mises stresses were evaluated in jaw bones and implant–abutment complex by a finite element method. The thread pitch ranged from 0.5 mm to 1.6 mm. Results suggested that under axial load, the maximum equivalent stresses in cortical bone, cancellous bone and implant–abutment complex decreased by 6.7%, 55.2% and 22.3%, respectively with the variation of thread pitch; and under buccolingual load, 2.7%, 22.4% and 13.0%, respectively. When thread pitch exceeded 0.8 mm, minimum stresses were obtained. Data indicated that cancellous bone was more sensitive to thread pitch than cortical bone did; thread pitch played a great role in protecting dental implant under axial load than under buccolingual load; and thread pitch exceeding 0.8 mm were optimal selection for a screwed implant by biomechanical consideration.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Advances in Engineering Software - Volume 40, Issue 7, July 2009, Pages 474–478
نویسندگان
, , , , , , ,