کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5706025 1603291 2016 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Pelvic floor muscle reflex activity during coughing - an exploratory and reliability study
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Pelvic floor muscle reflex activity during coughing - an exploratory and reliability study
چکیده انگلیسی

ObjectivesActivities that provoke stress urinary incontinence (SUI) rapidly increase the intra-abdominal pressure and the impact loading on the pelvic floor muscles (PFMs). Coughing can cause urinary leakage and is often used to test SUI. However, PFM characteristics during coughing, including their reliability, have not been investigated. Here, we used electromyography (EMG) to describe PFM pre-activity and reflexivity during coughing and examined the reliability of the measurements.MethodsThis was an exploratory and reliability study including 11 young healthy women to characterize EMG reflex activity in PFMs during coughing. We describe 6 variables, averaged over 3 coughs per subject, and tested their reliability (intraclass correlation coefficient 3,1 [ICC(3,1)] and ICC(3,k), related standard error of measurement (SEM) and minimal difference [MD]). The variables represented the mean EMG activity for PFMs during 30-ms time intervals of pre-activity (initial time point of coughing [T0] and minus 30 ms) and reflex activity (T0-30, 30-60, 60-90, 90-120 and 120-150 ms after T0) of stretch-reflex latency responses.ResultsThe mean %EMG (normalized to maximal voluntary PFM contraction) for EMG variables was 35.1 to 52.2 and was significantly higher during coughing than for PFM activity at rest (mean 24.9 ± 3.7%EMG; P < 0.05). ICC(3,k) ranged from 0.67 to 0.91 (SEM 6.1-13.3%EMG and MD 16.7-36.8%EMG) and was higher than ICC(3,1) (range 0.40-0.77; SEM 9.0-18.0%EMG, MD 24.9-50.0%EMG).ConclusionsPFM activity during reflex latency response time intervals during coughing was significantly higher than at rest, which suggests PFM pre-activity and reflex activity during coughing. Although we standardized coughing, EMG variables for PFM activity showed poor reliability [good to excellent ICC(3,k) and fair to excellent ICC(3,1) but high SEM and MD]. Therefore, coughing is expected to be heterogeneous, with low reliability, in clinical test situations. Potential crosstalk from other muscles involved in coughing could limit the interpretation of our results.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Annals of Physical and Rehabilitation Medicine - Volume 59, Issues 5–6, December 2016, Pages 302-307
نویسندگان
, , , , , , ,