11th Congress of the Turkish Transplantation Centers Coordination AssociationThoracic transplantationShort-term Results of Heartmate 3 Ventricular Assist Device Implantation for End-Stage Heart Failure
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی عمل جراحی
پیش نمایش صفحه اول مقاله
11th Congress of the Turkish Transplantation Centers Coordination AssociationThoracic transplantationShort-term Results of Heartmate 3 Ventricular Assist Device Implantation for End-Stage Heart Failure
چکیده انگلیسی

ObjectiveTo report our initial experience with Heartmate 3 ventricular assist device (HM3) in cases with end-stage heart failure (ESHF).MethodsCharts of 8 ESHF patients who underwent HM3 implantation in our clinic from January to June 2016 (group 1) and 16 patients who underwent HM2 implantation during 2015 (group 2) were reviewed retrospectively. Demographics as well as pre- and early postoperative medical data were noted and statistically analyzed between the 2 groups.ResultsNo statistical difference was found in age or sex distribution between groups (P > .05). Mean Interagency Registry for Mechanically Assisted Circulatory Support scores were 2.13 ± 0.99 and 3.38 ± 0.72 in groups 1 and 2, respectively (P = .020). Mean cardiopulmonary bypass time, and chest tube drainage fluid volume and blood product requirement during intensive care unit (ICU) stay were 64.0 ± 13.9 minutes, 1,112.5 ± 516.7 mL, and 318.8 ± 271.2 mL, respectively, in group 1 and 89.0 ± 33.3 minutes, 2,081.3 ± 1,696.0 mL, and 1,118.8 ± 1,010.8 mL in group 2 (P = .027, P = .019, and P = .040, respectively). Need for surgical revision and early mortality were not evident for group 1, although 4 cases (25.0%) required revision surgery, and early mortality was seen in 3 cases (18.8%) in group 2 (P = .121 and P = .190, respectively). Mean durations of ICU stay and total postoperative hospitalization were 5.9 ± 2.0 and 18.3 ± 5.5 days, respectively in group 1 and 6.2 ± 4.3 and 18.0 ± 6.9 days in the surviving 13 patients of the group 2 (P = .645 and P = .697, respectively).ConclusionsWith its shorter implantation time and reduced blood product requirement in the early postoperative period, the HM3 system was found to be safe and effective in ESHF treatment.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Transplantation Proceedings - Volume 49, Issue 3, April 2017, Pages 599-602