کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5732277 1611939 2017 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Original ResearchLaparoscopic ventral hernia repair with composite mesh: Analysis of risk factors for recurrence in 185 patients with 5 years follow-up
ترجمه فارسی عنوان
بررسی اصلی فتق فتاری فقرات لپاروسکوپیک با مش ترکیبی: بررسی عوامل خطر عود در 185 بیمار با پیگیری 5 ساله
کلمات کلیدی
لاپاروسکوپی، فتق انقباض فتق فقرات، مش کامپوزیت ضربه زدن. مسدود کردن،
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی عمل جراحی
چکیده انگلیسی


- The work is the result of the analysis of a case series conducted by a single surgical center on the effectiveness of laparoscopic surgical treatment of incisional hernias and primitive in order to identify the factors related to the patient and related to surgical technique that may influence the onset of recurrence.
- From the analysis we have shown that patients with recurrence were those with ASA score III, those with a BMI> 30 kg/m2, or those with wall> 5 cm defect (larger diameter), or those in which the overlap of the mesh is was <5 cm.
- In our surgical center these interventions were conducted by a dedicated team, and already expert in the field of advanced laparoscopic colorectal surgery and obesity.

BackgroundLaparoscopic ventral hernia repair is widely used although its clinical indications are often debated. The aim of this study is to describe our surgical experience in order to establish the safety, efficacy, feasibility of laparoscopic ventral hernia repair and to identify the factors that influence the risk of recurrence in a group of patients treated with only one type of prosthetic mesh and by the same surgical team.Materials and methodsBetween January 2007 and December 2016, 512 patients were admitted to the General and Urgent Surgery Unit, with diagnosis of ventral hernia. Of these, 244 were operated laparoscopically and 268 in a traditional open surgery. In 244 patients treated by laparoscopy we always used a composite mesh: 185 Parietex™ Composite mesh (Medtronic-Covidien, Minneapolis, USA), the remaining other with other types of prosthetic mesh. The type and size of surgical defects, features of surgical technique, length of hospital stay, rate of conversion, morbidity, mortality, and rate of recurrence at 5 years follow-up were retrospective analysed on the 185 patients who underwent surgery with Parietex™ Composite mesh.ResultsWe performed 185 laparoscopic ventral hernia repair with Parietex™ Composite mesh: 108 (58%) for incisional hernias and 77 (42%) for primary abdominal wall hernias. Mean age was 58 years (19-80). The mean size of abdominal defect was 5 cm (1,5-18), mean BMI was 30,4 kg/m2 (21-47), mean overlap of the mesh was 5 cm (3-6). The mean operative time was 54 min (30-180) and conversion rate was 3,2%. In 61 patients (33%) we performed a transversus abdominis plane block (T.A.P. block) to reduce postoperative pain. The mean length of hospital stay was 5 days (1-26) (2 days, mean value, in patient with preoperative T.A.P. block). The mortality rate was 0%; overall morbidity was 15,6%. At 5-year follow-up we observed 13 (7%) hernia recurrences. The features of patients with recurrence were as follows: mean age 50 years (19-74), mean ASA Score 3 (2-3), mean BMI 31 kg/m2 (21-44), mean size of hernial defect 7,5 cm (larger diameter), mean overlap 4,5 cm (3-6).ConclusionsLaparoscopic repair of ventral hernia using composite mesh is an effective and safe procedure particularly suitable in the following cases: median and paramedian defects, diameter of defect between 5 and 15 cm, “swiss cheese” defects, obesity. In our experience the factors related to the patient and the surgical technique that may influence the onset of early or late recurrence as the follows: a defect size >5 cm (W2 of EHS Classification), an overlap of the mesh < 5 cm, a BMI of 30 kg/m2 or superior and the presence of significant comorbidities (ASA score: 3). Finally, we observed that the T.A.P. Block preoperative procedure can lead to reduced the clinical costs through a lower administration of analgesics used and a lower length of stay.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Surgery - Volume 40, April 2017, Pages 38-44
نویسندگان
, , , , , , , , , ,