کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5737231 1614580 2017 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A general protocol of ultra-high resolution MR angiography to image the cerebro-vasculature in 6 different rats strains at high field
موضوعات مرتبط
علوم زیستی و بیوفناوری علم عصب شناسی علوم اعصاب (عمومی)
پیش نمایش صفحه اول مقاله
A general protocol of ultra-high resolution MR angiography to image the cerebro-vasculature in 6 different rats strains at high field
چکیده انگلیسی


- MR angiography in six different rat strains at high field.
- Robust time-of-flight protocol to image the cerebro-vasculature of the rat.
- Visualization of the hypothalamic and anterior choroidal artery.
- Detection of the posterior inferior cerebellar artery.
- Simple post-processing to aid visualization.

BackgroundDifferences in the cerebro-vasculature among strains as well as individual animals might explain variability in animal models and thus, a non-invasive method tailored to image cerebral vessel of interest with high signal to noise ratio is required.New methodExperimentally, we describe a new general protocol of three-dimensional time-of-flight magnetic resonance angiography to visualize non-invasively the cerebral vasculature in 6 different rat strains. Flow compensated angiograms of Sprague Dawley, Wistar Kyoto, Lister Hooded, Long Evans, Fisher 344 and Spontaneous Hypertensive Rat strains were obtained without the use of contrast agents. At 11.7 T using a repetition time of 60 ms, an isotropic resolution of up to 62 μm was achieved; total imaging time was 98 min for a 3D data set.ResultsThe visualization of the cerebral arteries was improved by removing extra-cranial vessels prior to the calculation of maximum intensity projection to obtain the angiograms. Ultimately, we demonstrate that the newly implemented method is also suitable to obtain angiograms following middle cerebral artery occlusion, despite the presence of intense vasogenic edema 24 h after reperfusion.Comparison with existing methodsThe careful selection of the excitation profile and repetition time at a higher static magnetic field allowed an increase in spatial resolution to reliably detect of the hypothalamic artery, the anterior choroidal artery as well as arterial branches of the peri-amygdoidal complex and the optical nerve in six different rat strains.ConclusionsMR angiography without contrast agent can be utilized to study cerebro-vascular abnormalities in various animal models.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Neuroscience Methods - Volume 289, 1 September 2017, Pages 75-84
نویسندگان
, , , , , , ,