کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5748908 1619148 2017 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
PAH emissions from old and new types of domestic hot water boilers
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم محیط زیست شیمی زیست محیطی
پیش نمایش صفحه اول مقاله
PAH emissions from old and new types of domestic hot water boilers
چکیده انگلیسی


- Two old-type and three modern domestic heating boilers were studied.
- Different types of solid fuel including illegally used mixed fuel were combusted.
- Mixed fuel had the highest emission factors of PAHs in over-fire boiler.
- The combustion of dry wood produced more PAHs than wet wood at reduced output.
- Boilers of modern construction produced the lowest PAHs at nominal output.

Five different domestic heating boilers (automatic, over-fire, with down-draft combustion and gasification) and three types of fuel (lignite, wood and mixed fuel) were examined in 25 combustion tests and correlated with the emissions of particulate matter (PM), carbon monoxide (CO), total organic carbon (TOC) and 12 polycyclic aromatic hydrocarbons (PAHs with MW = 178-278 g/mol) focusing on particle phase. However, the distribution of 12 PAHs in gas phase was considered as well due to the presence mainly of lighter PAHs in gas phase. The PAHs, as well as the CO and TOC, are the indicators of incomplete combustion, and in this study PAH emission increased significantly with increasing emissions of CO and TOC. The PAHs were mainly detected on PM2.5, their contents were increasing linearly with increasing PM2.5 emissions. The highest emission factors of PAHs were measured for boilers of old construction, such as over-fire boiler (5.8-929 mg/kg) and boiler with down-draft combustion (3.1-54.1 mg/kg). Modern types of boilers produced much lower emissions of PAHs, in particular, automatic boiler (0.3-3.3 mg/kg) and gasification boilers (0.2-6.7 mg/kg). In general, the inefficient combustion at reduced output of boilers generated 1.4-17.7 times more emissions of PAHs than the combustion at nominal output of boilers. It is recommended to operate boilers at nominal output with sufficient air supply and to use the proper fuel to minimise PAHs emissions from domestic heating appliances.

99

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Environmental Pollution - Volume 225, June 2017, Pages 31-39
نویسندگان
, , , , , , , , , ,