کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5794453 1554304 2016 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Dynamic computed tomography of the pituitary gland using a single slice scanner in dogs with pituitary-dependent hypercortisolism
ترجمه فارسی عنوان
پویایی توموگرافی کامپیوتری غده هیپوفیز با استفاده از یک اسکنر تکه در سگ ها با هیپوفیزیک وابسته به هیپوفیز
کلمات کلیدی
سگ، توموگرافی کامپیوتری دینامیک، هیپرکورتیزلیسم، هیپوفیزکتومی، غده هیپوفیز،
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم کشاورزی و بیولوژیک علوم دامی و جانورشناسی
چکیده انگلیسی


- The pituitary flush was seen equally frequently in MSDS and SSDS.
- The flush was seen more frequently in non-enlarged pituitaries.
- The surgeon's prediction of the nature of removed pituitary tissue was inconclusive.
- Complete hypophysectomy is still the preferred surgical technique in dogs.
- When the surgeon identifies the neurohypophysis, it may be left in place.

Selective removal of the pituitary adenoma has not been advocated in dogs with pituitary-dependent hypercortisolism because the pituitary adenoma is usually not visualized on routine computed tomography (CT).Dynamic pituitary CT scanning is aimed at the detection of the pituitary flush and, indirectly, at the presence and position of the adenoma. The first aim of this retrospective study was to compare findings of a multiple slice dynamic scanning protocol with those of a single slice dynamic protocol using a single slice CT scanner. The second aim was to compare the CT findings with surgical findings, and surgical findings with histopathological findings.Computed tomography with single and multiple slice dynamic scanning protocols was performed in 86 dogs with pituitary-dependent hypercortisolism. Thirty dogs underwent transsphenoidal hypophysectomy and pituitary specimens were collected as tumor, normal, mixed and neurohypophyseal samples and processed for histology.The pituitary flush was not detected more frequent in multiple slice dynamic scanning series than in single slice dynamic scanning series. However, in non-enlarged pituitaries, the flush was seen significantly more frequently than in enlarged pituitaries.Prediction of the nature of the tissue during hypophysectomy by the surgeon was inconclusive.In conclusion, when using a single slice CT scanner, both single or multiple slice dynamic scanning protocols can be used for localization of the neurohypophyseal flush, and, indirectly, the adenoma. However, based on this study, the aim of surgery in dogs with pituitary-dependent hypercortisolism remains total adenohypophysectomy, and when the neurophypophysis is recognized, it may be left in situ.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Research in Veterinary Science - Volume 107, August 2016, Pages 42-49
نویسندگان
, , , ,