کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5825006 1119884 2015 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Original ResearchSalivary Cortisol Results Obtainable Within Minutes of Sample Collection Correspond With Traditional Immunoassays
ترجمه فارسی عنوان
نتایج اصلی تحقیق در مورد کورتیسول در عرض چند دقیقه نمونه ای که با ایمونویسی سنتی مطابقت دارد
کلمات کلیدی
روش های جمع آوری، کورتیزول، ایمونواسی تکنولوژی جریان جانبی تنظیم استرس،
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی پزشکی و دندانپزشکی (عمومی)
چکیده انگلیسی

PurposeCortisol is frequently assayed as a stress-responsive biomarker which changes over the course of minutes to meet the demands of a person's social context. Salivary cortisol is often used as a noninvasive sampling method that possesses important health implications. A critical barrier to psychobiological research that involves salivary cortisol is a time delay of days to months before cortisol results are obtained via immunoassay, long after the person is no longer proximate to the social context in which they provided the sample. The present study was designed to address this critical barrier through creation of a lateral flow test (LFT) cortisol device capable of measuring salivary cortisol within minutes of sample collection. The LFT is frequently used within commercial point-of-care settings to obtain rapid answers to the presence/absence of a biomarker. The present study extends the LFT into the research domain by presenting performance characteristics of a quantitative LFT that measures salivary cortisol within 20 minutes of sample collection.MethodsSaliva samples from 29 adults (15 men) were obtained in the morning and afternoon by using Passive Drool and then the Super·SAL Extra Collection Device (hereafter Super·SAL) and later assayed with LFT and a commercially available enzyme immunoassay.FindingsResults indicate the LFT correlated well with these collection methods (R = 0.872 with Super · SAL, R = 0.739 with Passive Drool, P < 0.0001) and at comparable levels to correspondence of Super · SAL with Passive Drool (R = 0.798, P < 0.0001) which were measured with the same assay.ImplicationsThese results open an exciting new possibility to integrate this technologic advance into stress research, including knowing and potentially changing the person's social context in a time-sensitive manner. Methodological improvements such as this have the possibility of refining conceptual models of stress reactivity and regulation.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Clinical Therapeutics - Volume 37, Issue 3, 1 March 2015, Pages 505-514
نویسندگان
, , , , , ,