In the “polarised regime” from 3Â bar upwards, flux was independent of pressure for all membranes and was assumed to be determined by the back diffusion transport. Despite the fact that both the PS100H and C100F membranes had the same cut-off (100Â kg/mol), the hydrophilic C100F showed a superior permeate flux. The strongest drop of flux with time due to oil fouling was observed for the C100F although it was hydrophilic. In the case of the PS100H, both FTIR and SEM showed that cake layer formation was not the cause of fouling. Meanwhile the SEM and FTIR results of fouled C100F provided evidence of adsorptive and gel formation fouling.