کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
582738 | 1453168 | 2008 | 7 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Lab-scale study on the application of In-Adit-Sulfate-Reducing System for AMD control
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
موضوعات مرتبط
مهندسی و علوم پایه
مهندسی شیمی
بهداشت و امنیت شیمی
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
As an alternative method, In-Adit-Sulfate-Reducing System (IASRS), the method of placing the SAPS inside the adit, to have temperature constant at about 15 °C, was suggested. Lab-scale model experiments of IASRS were carried out. The models 1 and 2 were run at 15 °C and 25 °C, respectively. The model 1 contained about a half of COD in the beginning of the operation than that of model 2. Metal removal ratios were higher than 90% in both systems. Both systems showed the sulfate removal ratios of 23% and 27%, respectively, which were still considerably low, even though higher than those of presently operating systems. However, since the synthetic AMD used was very low in pH (2.8) and very high in sulfate concentration, if some suggested modifications were applied to the standard design, it is presumed that the sulfate removal ratio would have increased.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Hazardous Materials - Volume 160, Issues 2â3, 30 December 2008, Pages 441-447
Journal: Journal of Hazardous Materials - Volume 160, Issues 2â3, 30 December 2008, Pages 441-447
نویسندگان
S.W. Ji, S.J. Kim,