کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
586573 878221 2012 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Sizing of safety valves for multi-purpose plants according to ISO 4126-10
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی بهداشت و امنیت شیمی
پیش نمایش صفحه اول مقاله
Sizing of safety valves for multi-purpose plants according to ISO 4126-10
چکیده انگلیسی

Multi-purpose plants are frequently protected with mechanical safety devices like safety valves or bursting disks. Due to many changes of recipes it must be checked regularly whether the safety devices are sufficiently sized. But the sizing procedure of individual safety devices can be very tedious. Therefore energy specific relief areas (effective relief area per kW of energy input) have been determined for approx. 60 typical solvents. They are indicated for reactors with safety devices which have a set pressure of 7 bar (abs) or 11 bar (abs). These values are independent of the size of the reactors for vaporizing systems and arbitrary safety valves. The energy specific relief areas allow the minimum required relief area quickly to recalculate if the energy input of the reactor is known. In addition, the application of solvents in multi-purpose plants can be evaluated from a safety point of few.The energy specific relief areas are calculated based on a relief of two-phase gas/liquid mixtures. The data have been determined with the non-equilibrium HNE-DS method, which takes into account the boiling delay of the liquid in the safety device and the slip between gases and liquids. The method is recommended in the international standard ISO 4126 part 10. In addition, practical advice and possible improvements are outlined. The method leads to significantly smaller relief areas than according to the API 520. For multi-purpose plants with available safety devices this method allows for a considerable expansion of the application range of reactors.


► ISO 4126-10 extended for a quick proof of safety concepts for multi-purpose plants.
► HNE-DS method extended to one set of equations for all inlet conditions.
► Valve sizing performed for multi-purpose plants considering 60 typical solvents.
► Method applicable as short cut sizing method for chemical and petrochemical plants.
► Limit of isenthalpic gas flow according to ISO 4126-1 included in HNE-DS model.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Loss Prevention in the Process Industries - Volume 25, Issue 1, January 2012, Pages 181–191
نویسندگان
,