کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5884184 1150152 2014 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
ORIGINAL ARTICLEPlacing a Saline Bag Underneath the Heart Enhances Transgastric Transesophageal Echocardiographic Imaging During Cardiac Displacement for Off-Pump Coronary Artery Bypass Surgery
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی بیهوشی و پزشکی درد
پیش نمایش صفحه اول مقاله
ORIGINAL ARTICLEPlacing a Saline Bag Underneath the Heart Enhances Transgastric Transesophageal Echocardiographic Imaging During Cardiac Displacement for Off-Pump Coronary Artery Bypass Surgery
چکیده انگلیسی

ObjectiveThe authors hypothesized that placing a saline bag (saline-filled surgical glove) underneath a displaced heart would improve ultrasound transmission for transgastric (TG) imaging and transesophageal echocardiography (TEE) to visualize left ventricular regional wall motion (LV-RWM) during cardiac displacement for off-pump coronary artery bypass (OPCAB) surgery.DesignProspective observational study.SettingTertiary University Hospital.ParticipantsAdult patients undergoing OPCAB surgery.InterventionsIntraoperative TEE examinationMeasurement and Main ResultsFor off-line analyses of LV-readable segments, mid-esophageal (ME, 4-chamber, 2-chamber, and long-axis) and TG (basal- and mid-short-axis) TEE views were recorded under 3 different intraoperative conditions in 13 cases of OPCAB surgery: Before cardiac displacement (Tcontrol), after cardiac displacement (Tdisplaced), and after placing the saline bag underneath the displaced heart (Tsaline-bag). There were more LV-readable segments in the 17-segment model using integrated ME and TG views(ME + TG views) at Tsaline-bag and Tcontrol (mean[95% confidence interval], 17[17-17] and 17[17-17]) than using ME+TG at Tdisplaced (15[15-16], P = 0.002 and P<0.001, respectively). Using ME + TG views provided more LV-readable segments in the 17-segment model than using ME views at Tsaline-bag (vs. 16[14-16], P < 0.001), but not at Tdisplaced (vs. 15[14-15]). Incidences of inadequate RWM monitoring (LV-readable segments<14/17 using ME + TG views) at Tsaline-bag and Tcontrol (all 0/13) were less frequent than at Tdisplaced (3/13, all P = 0.038). There were more LV-readable segments in TG basal- and mid-short-axis views at Tsaline-bag (median [range], 6[5-6] and 5[5-6]) than at Tdisplaced (0[0-2] and 0[0-1], all P < 0.05).ConclusionsPlacing a saline bag underneath the displaced heart enhances the ability of TEE to visualize global LV-RWM by improving TG TEE imaging during OPCAB surgery.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Cardiothoracic and Vascular Anesthesia - Volume 28, Issue 1, February 2014, Pages 42-48
نویسندگان
, , , , , , , , , , , , , , ,