کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5927041 1167663 2012 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Clinical InvestigationCongestive Heart FailurePercutaneous left ventricular partitioning in patients with chronic heart failure and a prior anterior myocardial infarction: Results of the PercutAneous Ventricular RestorAtion in Chronic Heart failUre PaTiEn
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Clinical InvestigationCongestive Heart FailurePercutaneous left ventricular partitioning in patients with chronic heart failure and a prior anterior myocardial infarction: Results of the PercutAneous Ventricular RestorAtion in Chronic Heart failUre PaTiEn
چکیده انگلیسی

ObjectivesThe aim of this study was to assess the feasibility, safety, and preliminary efficacy of a novel percutaneous left ventricular partitioning device (VPD) in patients with chronic heart failure (HF) and a prior anterior myocardial infarction.BackgroundAnterior myocardial infarction is frequently followed by left ventricular remodeling, HF, and increased long-term morbidity and mortality.MethodsThirty-nine patients were enrolled in a multinational, nonrandomized, longitudinal investigation. The primary end point was an assessment of safety, defined as the successful delivery and deployment of the VPD and absence of device-related major adverse cardiac events over 6 months. Secondary (exploratory) efficacy end points included changes in hemodynamics and functional status and were assessed serially throughout the study.ResultsVentricular partitioning device placement was not attempted in 5 (13%) of 39 subjects. The device was safely and successfully implanted in 31 (91%) of the remaining 34 patients or 79% of all enrolled patients. The 6-month rate of device-related major adverse cardiac event occurred in 5 (13%) of 39 enrolled subjects and 5 (15%) of 34 treated subjects, with 1 additional event occurring between 6 and 12 months. For patients discharged with the device to 12 months (n = 28), New York Heart Association class (2.5 ± 0.6 to 1.3 ± 0.6, P < .001) and quality-of-life scores (38.6 ± 6.1 to 28.4 ± 4.4, P < .002) improved significantly; however, the 6-minute hall walk distance (358.5 ± 20.4 m to 374.7 ± 25.6 m, P nonsignificant) only trended toward improvement.ConclusionsThe left VPD appears to be relatively safe and potentially effective in the treatment for patients with HF and a prior anterior myocardial infarction. However, these limited results suggest the need for further evaluation in a larger randomized controlled trial.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: American Heart Journal - Volume 163, Issue 5, May 2012, Pages 812-820.e1
نویسندگان
, , , , , , , , , ,