کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5928444 1167781 2014 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Design and rationale of the ANALYZE ST study: A prospective, nonrandomized, multicenter ST monitoring study to detect acute coronary syndrome events in implantable cardioverter-defibrillator patients
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Design and rationale of the ANALYZE ST study: A prospective, nonrandomized, multicenter ST monitoring study to detect acute coronary syndrome events in implantable cardioverter-defibrillator patients
چکیده انگلیسی

BackgroundIn the setting of ST-segment elevation myocardial infarction, timely restoration of normal blood flow is associated with improved myocardial salvage and survival. Despite improvements in door-to-needle and door-to-balloon times, there remains an unmet need with respect to improved symptom-to-door times. A prior report of an implanted device to monitor ST-segment deviation demonstrated very short times to reperfusion among patients with an acute coronary syndrome (ACS) with documented thrombotic occlusion. The goal of the ANALYZE ST study is to evaluate the safety and effectiveness of a novel ST-segment monitoring feature using an existing implantable cardioverter-defibrillator (ICD) among patients with known coronary artery disease.MethodsThe ANALYZE ST study is a prospective, nonrandomized, multicenter, pivotal Investigational Device Exemption study enrolling 5,228 patients with newly implanted ICD systems for standard clinical indications who also have a documented history of coronary artery disease. Patients will be monitored for 48 months, during which effectiveness of the device for the purpose of early detection of cardiac injury will be evaluated by analyzing the sensitivity of the ST monitoring feature to identify clinical ACS events. In addition, the safety of the ST monitoring feature will be evaluated through the assessment of the percentage of patients for which monitoring produces a false-positive event over the course of 12 months.ConclusionsThe ANALYZE ST trial is testing the hypothesis that the ST monitoring feature in the Fortify ST ICD system (St. Jude Medical, Inc., St. Paul, MN) (or other ICD systems with the ST monitoring feature) will accurately identify patients with clinical ACS events.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: American Heart Journal - Volume 168, Issue 4, October 2014, Pages 424-429.e1
نویسندگان
, , , , , , , , , , ,