کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
5930014 | 1572118 | 2016 | 8 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Prognostic Significance of Polymer Coatings in Zotarolimus-Eluting Stents
ترجمه فارسی عنوان
اهمیت پیش آگهی پوشش های پلیمری در استات های زوتارولیموس الوجود
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
موضوعات مرتبط
علوم پزشکی و سلامت
پزشکی و دندانپزشکی
کاردیولوژی و پزشکی قلب و عروق
چکیده انگلیسی
Polymer coatings on drug-eluting stents (DES) serve as a vehicle for delivery of antirestenotic drugs. Whether they influence outcomes for contemporary DES is unknown. The evolution of polymer coatings for zotarolimus-eluting stents (ZES) provides a natural experiment that facilitates such analysis. The Resolute ZES (R-ZES) uses the same antirestenotic drug as the Endeavor ZES (E-ZES) but has a more biocompatible polymer with enhanced drug release kinetics. However, there are limited data on the real-world comparative efficacy of R-ZES and the preceding E-ZES. Thus, we analyzed 17,643 patients who received either E-ZES or R-ZES from 2008 to 2014 from the British Columbia Cardiac Registry. A total of 9,869 patients (56%) received E-ZES and 7,774 patients (44%) received R-ZES. Compared with E-ZES, R-ZES was associated with lower 2-year mortality (4.1% vs 6.4%, p <0.001) and 2-year target vessel revascularization (TVR; 6.8% vs 10.7%, p <0.001). R-ZES use was an independent predictor of lower mortality rate and TVR. This was confirmed in propensity-matched analyses for 2-year mortality (hazard ratio [HR] 0.59, 95% CI 0.49 to 0.71, p <0.001) and 2-year TVR (HR 0.86, 95% CI 0.75 to 0.98, p = 0.032). Instrumental variable analyses demonstrated R-ZES to be associated with lower 2-year mortality (Π= â2.2%, 95% CI â4.3% to â0.2%, p = 0.032) and 2-year TVR (Π= â3.3% to 95% CI â6.1% to â0.7%, p = 0.015). Acknowledging the limitations of observational analyses, this study has shown that R-ZES was associated with lower long-term TVR and mortality. These data are reassuring for the newer R-ZES and demonstrate how polymer coatings may influence the clinical performance of DES with wider implications for future DES development and design.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The American Journal of Cardiology - Volume 117, Issue 5, 1 March 2016, Pages 735-742
Journal: The American Journal of Cardiology - Volume 117, Issue 5, 1 March 2016, Pages 735-742
نویسندگان
M. Bilal MD, Imad J. MD, Jehangir N. MD, Cara MD, Lillian MSc, Anthony MD, Eve MD, Albert W. MD, Steven MD, Simon D. MD, Anthony MD, British Columbia Cardiac Registry Investigators British Columbia Cardiac Registry Investigators,