کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5930074 1572119 2016 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Results of ENHANCED Implantable Cardioverter Defibrillator Programming to Reduce Therapies and Improve Quality of Life (from the ENHANCED-ICD Study)
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Results of ENHANCED Implantable Cardioverter Defibrillator Programming to Reduce Therapies and Improve Quality of Life (from the ENHANCED-ICD Study)
چکیده انگلیسی
Novel implantable cardioverter defibrillator (ICD) discrimination algorithms and programming strategies have significantly reduced the incidence of inappropriate shocks, but there are still gains to be made with respect to reducing appropriate but unnecessary antitachycardia pacing (ATP) and shocks. We examined whether programming a number of intervals to detect (NID) of 60/80 for ventricular tachyarrhythmia (VT)/ventricular fibrillation (VF) detection was safe and the impact of this strategy on (1) adverse events related to ICD shocks and syncopal events; (2) ATPs/shocks; and (3) patient-reported outcomes. The “ENHANCED Implantable Cardioverter Defibrillator programming to reduce therapies and improve quality of life” study (ENHANCED-ICD study) was a prospective, safety-monitoring study enrolling 60 primary and secondary prevention patients at the University Medical Center Utrecht. Patients implanted with any type of ICD with SmartShock technology and aged 18 to 80 years were eligible to participate. In all patients, a prolonged NID 60/80 was programmed. The cycle length for VT/fast VT/VF was 360/330/240 ms, respectively. Programming a NID 60/80 proved safe for ICD patients. Because of the new programming strategy, unnecessary ICD therapy was prevented in 10% of ENHANCED-ICD patients during a median follow-up period of 1.3 years. With respect to patient-reported outcomes, levels of distress were highest and perceived health status lowest at the time of implantation, which both gradually improved during follow-up. In conclusion, the ENHANCED-ICD study demonstrates that programming a NID 60/80 for VT/VF detection is safe for ICD patients and does not negatively impact their quality of life.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The American Journal of Cardiology - Volume 117, Issue 4, 15 February 2016, Pages 596-604
نویسندگان
, , , , , , ,