- Major complications occurred in a rate of 2.9% in a total amount of 1233 procedures.
- Complication rates decreased over the study period from 4.67% to 1.55%.
- The complication rate did not significantly differ in the RF and CB groups.
- CHA2DS2-VASc score was able to predict the risk to develop major complications.

BackgroundThe aim of this study was to assess the overall incidence of complications in a large sample of consecutive patients having undergone pulmonary vein (PV) isolation, evaluating also the rate of complications in radiofrequency (RF) and cryoballoon (CB) ablation technologies.Methods and resultsFrom January 2008 to December 2014, 1352 consecutive PV isolation procedures were performed in our center; a total amount of 1233 AF ablation procedures fulfilling inclusion criteria was finally taken into consideration for our analysis. A total of 642 procedures were performed using RF ablation technology and 591 using CB system. Serious adverse events occurred in 36 procedures (2.9%): specifically, vascular complications in 14 (1.1%); cardiac tamponade in 13 (1.0%); a thromboembolic event in 4 (0.3%); and atrial-esophageal fistula, PV intramural hematoma, retroperitoneal hematoma, pleural hematoma and persisting phrenic nerve palsy all occurred in 1 patient individually (0.1%). No deaths related to the procedure occurred. The complication rate did not significantly differ in the RF and CB groups (respectively, 3.6% vs 2.2%; p = 0.1). Complication rates considerably decreased over the study period from 4.67% in 2008 to 1.55% in 2014. Interestingly, each 1-point increase in the CHA2DS2-VASc score was found to increase by 51% the likelihood of a serious adverse event.ConclusionsThe incidence of serious adverse events following AF ablation procedures was 2.9%. Vascular complications were the most frequent complication followed by tamponade and thromboembolic events. The rate of complications considerably decreased over time. CHA2DS2-VASc score was found to be associated with higher risk of complications.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Cardiology - Volume 196, 1 October 2015, Pages 42-49
نویسندگان
, , , , , , , , , , , ,