کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5983166 1577151 2013 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Percutaneous Left Atrial Appendage Closure With the AMPLATZER Cardiac Plug Device in Patients With Nonvalvular Atrial Fibrillation and Contraindications to Anticoagulation Therapy
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Percutaneous Left Atrial Appendage Closure With the AMPLATZER Cardiac Plug Device in Patients With Nonvalvular Atrial Fibrillation and Contraindications to Anticoagulation Therapy
چکیده انگلیسی

ObjectivesThe aim of this study was to evaluate the results associated with left atrial appendage closure (LAAC) with the AMPLATZER Cardiac Plug (ACP) (St. Jude Medical, Minneapolis, Minnesota) in patients with nonvalvular atrial fibrillation and absolute contraindications to anticoagulation therapy.BackgroundFew data exist on the late outcomes after LAAC in patients with absolute contraindications to warfarin.MethodsA total of 52 patients with nonvalvular atrial fibrillation underwent LAAC with the ACP device in 7 Canadian centers. Most patients received short-term (1 to 3 months) dual-antiplatelet therapy after the procedure and single-antiplatelet therapy thereafter. A transesophageal echocardiography was performed in 74% of patients at the 6-month follow-up. No patient was lost to follow-up (≥12 months in all patients).ResultsThe mean age and median (interquartile range) CHADS2 score were 74 ± 8 years and 3 (2 to 4), respectively. The procedure was successful in 98.1% of the patients, and the main complications were device embolization (1.9%) and pericardial effusion (1.9%), with no cases of periprocedural stroke. At a mean follow-up of 20 ± 5 months, the rates of death, stroke, systemic embolism, pericardial effusion, and major bleeding were 5.8%, 1.9%, 0%, 1.9%, and 1.9%, respectively. The presence of mild peridevice leak was observed in 16.2% of patients at the 6-month follow-up as evaluated by transesophageal echocardiography. There were no cases of device thrombosis.ConclusionsIn patients with nonvalvular atrial fibrillation at high risk of cardioembolic events and absolute contraindications to anticoagulation, LAAC using the ACP device followed by dual-/single-antiplatelet therapy was associated with a low rate of embolic and bleeding events after a mean follow-up of 20 months. No cases of severe residual leak or device thrombosis were observed at the 6-month follow-up.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Cardiology - Volume 62, Issue 2, 9 July 2013, Pages 96-102
نویسندگان
, , , , , , , , , , , ,