کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5998360 1181439 2014 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Average current is better than peak current as therapeutic dosage for biphasic waveforms in a ventricular fibrillation pig model of cardiac arrest
ترجمه فارسی عنوان
متوسط ​​جریان بهتر از جریان پیک به عنوان دوز درمان برای شکل موج دو فازی در یک مدل خوک فیبریلاسیون بطنی از دست رفتن قلب
کلمات کلیدی
دستگیری قلبی، فیبریلاسیون بطنی، متوسط ​​جریان، جریان جاری، موفقیت شوک،
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
چکیده انگلیسی

ObjectiveDefibrillation current has been shown to be a clinically more relevant dosing unit than energy. However, the effects of average and peak current in determining shock outcome are still undetermined. The aim of this study was to investigate the relationship between average current, peak current and defibrillation success when different biphasic waveforms were employed.MethodsVentricular fibrillation (VF) was electrically induced in 22 domestic male pigs. Animals were then randomized to receive defibrillation using one of two different biphasic waveforms. A grouped up-and-down defibrillation threshold-testing protocol was used to maintain the average success rate of 50% in the neighborhood. In 14 animals (Study A), defibrillations were accomplished with either biphasic truncated exponential (BTE) or rectilinear biphasic waveforms. In eight animals (Study B), shocks were delivered using two BTE waveforms that had identical peak current but different waveform durations.ResultsBoth average and peak currents were associated with defibrillation success when BTE and rectilinear waveforms were investigated. However, when pathway impedance was less than 90 Ω for the BTE waveform, bivariate correlation coefficient was 0.36 (p = 0.001) for the average current, but only 0.21 (p = 0.06) for the peak current in Study A. In Study B, a high defibrillation success (67.9% vs. 38.8%, p < 0.001) was observed when the waveform delivered more average current (14.9 ± 2.1 A vs. 13.5 ± 1.7 A, p < 0.001) while keeping the peak current unchanged.ConclusionIn this porcine model of VF, average current was better than peak current to be an adequate parameter to describe the therapeutic dosage when biphasic defibrillation waveforms were used.The institutional protocol number: P0805.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Resuscitation - Volume 85, Issue 10, October 2014, Pages 1399-1404
نویسندگان
, , , , ,