The utility of near-infrared spectroscopy in the regression of low-frequency physiological noise from functional magnetic resonance imaging data
موضوعات مرتبط
علوم زیستی و بیوفناوری علم عصب شناسی علوم اعصاب شناختی
پیش نمایش صفحه اول مقاله
The utility of near-infrared spectroscopy in the regression of low-frequency physiological noise from functional magnetic resonance imaging data
چکیده انگلیسی
Near-infrared spectroscopy (NIRS) signals have been shown to correlate with resting-state BOLD-fMRI data across the whole brain volume, particularly at frequencies below 0.1 Hz. While the physiological origins of this correlation remain unclear, its existence may have a practical application in minimizing the background physiological noise present in BOLD-fMRI recordings. We performed simultaneous, resting-state fMRI and 28-channel NIRS in seven adult subjects in order to assess the utility of NIRS signals in the regression of physiological noise from fMRI data. We calculated the variance of the residual error in a general linear model of the baseline fMRI signal, and the reduction of this variance achieved by including NIRS signals in the model. In addition, we introduced a sequence of simulated hemodynamic response functions (HRFs) into the resting-state fMRI data of each subject in order to quantify the effectiveness of NIRS signals in optimizing the recovery of that HRF. For comparison, these calculations were also performed using a pulse and respiration RETROICOR model. Our results show that the use of 10 or more NIRS channels can reduce variance in the residual error by as much as 36% on average across the whole cortex. However the same number of low-pass filtered white noise regressors is shown to produce a reduction of 19%. The RETROICOR model obtained a variance reduction of 6.4%. Our HRF simulation showed that the mean-squared error (MSE) between the recovered and true HRFs is reduced by 21% on average when 10 NIRS channels are applied and by introducing an optimized time lag between the NIRS and fMRI time series, a single NIRS channel can provide an average MSE reduction of 14%. The RETROICOR model did not provide a significant change in MSE. By each of the metrics calculated, NIRS recording is shown to be of significant benefit to the regression of low-frequency physiological noise from fMRI data.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: NeuroImage - Volume 59, Issue 4, 15 February 2012, Pages 3128-3138
نویسندگان
, , , , ,