کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6033894 1188750 2011 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Technical NoteSimultaneous recording of ECoG and intracortical neuronal activity using a flexible multichannel electrode-mesh in visual cortex
موضوعات مرتبط
علوم زیستی و بیوفناوری علم عصب شناسی علوم اعصاب شناختی
پیش نمایش صفحه اول مقاله
Technical NoteSimultaneous recording of ECoG and intracortical neuronal activity using a flexible multichannel electrode-mesh in visual cortex
چکیده انگلیسی

Electrocorticogram (ECoG) is a well-balanced methodology for stably mapping brain surface local field potentials (LFPs) over a wide cortical region with high signal fidelity and minimal invasiveness to the brain tissue. To directly compare surface ECoG signals with intracortical neuronal activity immediately underneath, we fabricated a flexible multichannel electrode array with mesh-form structure using micro-electro-mechanical systems. A Parylene-C-based “electrode-mesh” for rats contained a 6 × 6 gold electrode array with 1-mm interval. Specifically, the probe had 800 × 800 μm2 fenestrae in interelectrode spaces, through which simultaneous penetration of microelectrode was capable. This electrode-mesh was placed acutely or chronically on the dural/pial surface of the visual cortex of Long-Evans rats for up to 2 weeks. We obtained reliable trial-wise profiles of visually evoked ECoG signals through individual eye stimulation. Visually evoked ECoG signals from the electrode-mesh exhibited as well or larger signal amplitudes as intracortical LFPs and less across-trial variability than conventional silver-ball ECoG. Ocular selectivity of ECoG responses was correlated with that of intracortical spike/LFP activities. Moreover, single-trial ECoG signals carried sufficient information for predicting the stimulated eye with a correct performance approaching 90%, and the decoding was significantly generalized across sessions over 6 hours. Electrode impedance or signal quality did not obviously deteriorate for 2 weeks following implantation. These findings open up a methodology to directly explore ECoG signals with reference to intracortical neuronal sources and would provide a key to developing minimally invasive next-generation brain-machine interfaces.

Graphical Abstract580Research highlights► Mesh-form micro electrode array of 20µm-thickness was developed for ECoG recording. ► 'Fenestrae' in mesh improved fitting and allowed simultaneous use of other probes. ► VEPs were stably recorded in both acute and chronic preparations of rat V1. ► Qualities of ECoG signal from electrode mesh were comparable to intracortical LFP. ► Stimulated eye was decoded from mesh ECoG with a single-trial accuracy of nearly 90%.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: NeuroImage - Volume 54, Issue 1, 1 January 2011, Pages 203-212
نویسندگان
, , , , , ,