کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
6048673 | 1191647 | 2015 | 10 صفحه PDF | دانلود رایگان |
- Three burns dressings for partial thickness burns in children were compared.
- Wound re-epithelialization time was significantly faster in children treated with Mepilex Agâ¢.
- Dressings with silicone interfaces had significantly lower pain levels at dressing changes.
- No infections were detected for the course of the study.
BackgroundThis study compared the effects of three silver dressing combinations on small to medium size acute partial thickness burns in children, focusing on re-epithelialization time, pain and distress during dressing changes.MethodChildren (0-15 years) with clean, â¤10% total body surface area (TBSA) partial thickness burns who met the inclusion criteria were included in the study. Children received either (1) Acticoatâ¢; (2) Acticoat⢠with Mepitelâ¢; or (3) Mepilex Ag⢠dressings. Measures of burn re-epithelialization, pain, and distress were recorded at dressing changes every 3-5 days until full re-epithelialization occurred.ResultsOne hundred and three children were recruited with 96 children included for analysis. No infections were detected for the course of the study. When adjusted for burn depth, Acticoat⢠significantly increased the expected days to full re-epithelialization by 40% (IRR = 1.40; 95% CI: 1.14-1.73, p < 0.01) and Acticoat⢠with Mepitel⢠significantly increased the expected days to full re-epithelialization by 33% (IRR = 1.33; 95% CI: 1.08-1.63, p â¤Â 0.01) when compared to Mepilex Agâ¢. Expected FLACC scores in the Mepilex Ag⢠group were 32% lower at dressing removal (p = 0.01) and 37% lower at new dressing application (p = 0.04); and scores in the Acticoat⢠with Mepitel⢠group were 23% lower at dressing removal (p = 0.04) and 40% lower at new dressing application (p < 0.01), in comparison to the Acticoat⢠group. Expected Visual Analog Scale-Pain (VAS-P) scores were 25% lower in the Mepilex Ag⢠group at dressing removal (p = 0.04) and 34% lower in the Acticoat⢠with Mepitel⢠group (p = 0.02) at new dressing application in comparison to the Acticoat⢠group. There was no significant difference between the Mepilex Ag⢠and the Acticoat⢠with Mepitel⢠groups at all timepoints and with any pain measure.ConclusionMepilex Ag⢠is an effective silver dressing, in terms of accelerated wound re-epithelialization time (compared to Acticoat⢠and Acticoat⢠with Mepitelâ¢) and decreased pain during dressing changes (compared to Acticoatâ¢), for clean, <10% TBSA partial thickness burns in children.
Journal: Burns - Volume 41, Issue 5, August 2015, Pages 946-955