کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
6082620 | 1205970 | 2016 | 9 صفحه PDF | دانلود رایگان |
BackgroundWe sought to compare the incidence of complications after fixation of displaced femoral neck fractures in young adults treated with fixed-angle devices versus multiple cancellous screws and a trochanteric lag screw (Pauwel screw).MethodsWe conducted a retrospective cohort study at a level I trauma centre. Sixty-two skeletally mature patients (age range, 16-60 years) with displaced femoral neck fractures were included in the study. Forty-seven were treated with a fixed-angle device (sliding hip plate with screw or helical blade) and 15 with multiple cancellous screws placed in a Pauwel configuration. The main outcome measure was postoperative complication of osteonecrosis or nonunion treated with a surgical procedure.ResultsSignificantly fewer failures occurred in the fixed-angle group (21%) than in the screws group (60%) (p = 0.008). Osteonecrosis was rare in the fixed-angle group, occurring in 2% of cases versus 33% of cases in the screws group (p = 0.002). Consistent with previous studies, good to excellent reductions were associated with a failure rate of 25% and fair to poor reductions were associated with a failure rate of 55% (p = 0.07). The best-case scenario of a good to excellent reduction stabilised with a fixed-angle device yielded a success rate of 85%.ConclusionIn young patients with displaced high-energy femoral neck fractures, fixed-angle devices resulted in fewer treatment failures than did Pauwel screws.
Journal: Injury - Volume 47, Issue 8, August 2016, Pages 1676-1684