کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6104924 1211143 2013 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Research ArticlePortal uptake function in veno-occlusive regions evaluated by real-time fluorescent imaging using indocyanine green
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی بیماری‌های گوارشی
پیش نمایش صفحه اول مقاله
Research ArticlePortal uptake function in veno-occlusive regions evaluated by real-time fluorescent imaging using indocyanine green
چکیده انگلیسی

Background & AimsAlthough recent advances in preoperative imaging have enabled accurate estimation of the regional liver volume with venous occlusion, the extent of functional decrease in such regions remains unclear. In this study, the portal uptake function in postoperative veno-occlusive regions and non-veno-occlusive regions was evaluated by intraoperative fluorescent imaging after intravenous injection of indocyanine green (ICG).MethodsIn 22 liver resection patients and 23 recipients and 18 donors of liver transplantation, fluorescent intensity on the remnant liver or the liver graft was evaluated in real time following intravenous injection of ICG (0.0025 mg per 1 ml of remnant liver volume).ResultsPlateau ICG concentrations were significantly lower in the veno-occlusive regions (CVO) than in the non-veno-occlusive regions (CNon) in liver resection patients (median [range], 0.75 [0.29-2.0] μg/ml vs. 3.0 [0.46-6.4] μg/ml, p <0.001), donors (0.69 [0.29-1.9] μg/ml vs. 2.4 [0.46-6.4] μg/ml, p <0.001), and recipients (0.75 [0.34-1.8] μg/ml vs. 1.8 [0.54-6.4] μg/ml, p <0.001). Distributions of the CVO/CNon and the ratio of the hepatic uptake rate constant in the veno-occlusive regions to that in non-veno-occlusive regions were both around 40% (mean ± standard deviation, 0.36 ± 0.17 and 0.42 ± 0.16, respectively). When the functional remnant liver volume was calculated as a sum of non-veno-occlusive regions and veno-occlusive regions multiplied by CVO/CNon, its ratio to the total liver volume was correlated with the improved postoperative/preoperative ratio of prothrombin time.ConclusionsPortal uptake function in veno-occlusive regions is approximately 40% of that in non-veno-occlusive regions. Intraoperative ICG-fluorescent imaging enables real-time evaluation of the extent of the functional decrease in veno-occlusive regions, enhancing accurate estimation of the hepatic functional reserve for determining the surgical indications and procedures.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Hepatology - Volume 58, Issue 2, February 2013, Pages 247-253
نویسندگان
, , , , , , , , , , , , ,