کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6196205 1602571 2016 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Interpreting the corneal response to oxygen: Is there a basis for re-evaluating data from gas-goggle studies?
ترجمه فارسی عنوان
تفسیر پاسخ قرنیه به اکسیژن: آیا پایه ای برای ارزیابی مجدد داده ها از مطالعات تفکیک گازی وجود دارد؟
موضوعات مرتبط
علوم زیستی و بیوفناوری ایمنی شناسی و میکروب شناسی ایمونولوژی و میکروب شناسی (عمومی)
چکیده انگلیسی


- An additional source of ocular surface oxygenation in the open eye is proposed.
- Oxygen derived from the eyelid vasculature may influence physiological responses.
- Achieving open eye, ocular surface anoxia may not be possible by atmospheric manipulation alone.
- Considering lid derived oxygen eliminates previous discrepancies in corneal swelling response.
- Data obtained in gas-goggle experiments may need adjustment for these effects.

When anoxia (0% oxygen) is created within a gas-tight goggle, ocular physiological responses, including corneal swelling, limbal hyperaemia and pH change, are known to vary, depending on the presence or absence of a low, oxygen transmissibility contact lens. A new theory is proposed to account for this discrepancy based on the concept of lid derived oxygen, whereby oxygen originating from the vascular plexus of the palpebral conjunctiva supplements that available to the ocular surface in an open, normally blinking eye, even when the surrounding gaseous atmosphere is anoxic. The effect of a lid derived contribution to corneal oxygenation was assessed by using existing experimental data to model open-eye, corneal swelling behavior as a function of atmospheric oxygen content, both with and without the presence of a contact lens. These models predict that under atmospheric anoxia, contact lens wear results in 13.2% corneal swelling compared with only 5.4% when the lens was absent. Lid derived oxygen acts to provide the ocular surface in the non-contact lens wearing, normally blinking, open-eye with up to 4.7% equivalent oxygen concentration, even within the anoxic environment of a nitrogen filled goggle. Correcting for lid derived oxygen eliminates previously observed discrepancies in corneal swelling behavior and harmonizes the models for the contact lens wearing and gas-goggle cases. On this basis it is proposed that true anoxia at the ocular surface cannot be achieved by atmospheric manipulation (i.e. a gas-goggle) alone but requires an additional presence, e.g. a low, oxygen transmissibility contact lens, to prevent access to oxygen from the eyelids. Data from previously conducted experiments in which the gas-goggle paradigm was used, may have been founded on underestimates of the real oxygen concentration acting on the ocular surface at the time and if so, will require re-interpretation. Future work in this area should consider if a correction for lid derived oxygen is necessary.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Experimental Eye Research - Volume 151, October 2016, Pages 222-226
نویسندگان
, ,