کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6208724 1603981 2016 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Patient-Specific Total Knees Demonstrate a Higher Manipulation Rate Compared to “Off-the-Shelf Implants”
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Patient-Specific Total Knees Demonstrate a Higher Manipulation Rate Compared to “Off-the-Shelf Implants”
چکیده انگلیسی

Patient-specific total knee replacements have been designed in hopes of providing better functional outcomes compared to “off-the-shelf” implants in primary total knee arthroplasty (TKA). We prospectively evaluated manipulation rates and clinical outcomes of 21 patient-specific TKAs matched with 42 posterior-stabilized and 11 cruciate-retaining “off-the-shelf” TKAs. Postoperatively, the patient-specific group had a range of motion significantly less than both control groups (P < 0.01). Six of the 21 (28.6%) patient-specific TKAs required manipulation to improve range of motion. No manipulations were reported in either control groups. At minimum two-year follow-up the patient-specific TKAs had similar motion, but worse satisfaction and KSS pain scores. Radiographic analysis provided no insight to the cause of stiffness. Early manipulation is recommended for stiffness with patient-specific TKA.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Arthroplasty - Volume 31, Issue 1, January 2016, Pages 107-111
نویسندگان
, ,