کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6209315 1603995 2014 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Cementless Bipolar Hemiarthroplasty Using a Micro-Arc Oxidation Coated Stem in Patients with Displaced Femoral Neck Fractures
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Cementless Bipolar Hemiarthroplasty Using a Micro-Arc Oxidation Coated Stem in Patients with Displaced Femoral Neck Fractures
چکیده انگلیسی

Femoral stem fixation for displaced femoral neck fractures in osteoporotic patients is an ongoing debate. We evaluated the outcome of 136 cementless bipolar hemiarthroplasty using a Micro-arc oxidation (MAO) coated stem. All patients survived the procedure and were discharged from the hospital. Thirty- and 90-day mortality rates were 0.7% and 2.2%, respectively. Ninety-eight hips were followed for a minimum of 2 years (mean, 44 months) postoperatively. Three stems were revised because of a periprosthetic fracture. Although cortical stress shielding around the stem was observed in 3 hips, there was no loosening or osteolysis. Cementless bipolar hemiarthroplasty using a MAO-coated stem is a useful and safe option to treat displaced femoral neck fractures.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Arthroplasty - Volume 29, Issue 12, December 2014, Pages 2388-2392
نویسندگان
, , , , ,