Circulation rates of boiling liquids in a vertical tube
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی تصفیه و جداسازی
پیش نمایش صفحه اول مقاله
Circulation rates of boiling liquids in a vertical tube
چکیده انگلیسی

An experimental study of heat transfer to boiling liquids under natural convective flow has been carried out in a single tube vertical thermosiphon reboiler to investigate the effect of heat flux and submergence on circulation rates. The test liquids used were distilled water, various concentrations of propan-2-ol in water and their azeotrope. The test section was an electrically heated stainless steel tube of 25.56 mm i.d., 28.85 mm o.d. and 1900 mm long with twenty-one spot welded copper constantan thermocouples to measure the variations in wall temperature along its axis. The uniform heat fluxes in the range of 3.5–42.4 kW/m2 were employed while inlet liquid sub-cooling varied from 0.2 to 30.7 °C. The liquid submergence levels were maintained in the range 30–100%. The typical experimental data has been graphically presented and discussed. An empirical correlation has been developed from the experimental data of the present study through regression analysis.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Chemical Engineering Research and Design - Volume 86, Issue 5, May 2008, Pages 499–507