• A prediction model was developed to calculate the membrane defect size.
• The measured data goes with similar trend with model D.
• Nanoparticle test has 39.33% probability to have a theoretic resolution of 3 μm.
An alternative ultrafiltration membrane integrity test utilizing magnetic nanoparticle as a surrogate has been investigated in previous studies, but the absence of a feasible estimation model for the degree of membrane damage causes that this simple membrane integrity test would be not applied easily. This study proposed a calculating model to predict membrane defect size, and investigated the theoretic resolution of the integrity test method. The results obtained with the evolved prediction model D, which is based on Darcy’s law and Bernoulli equation, were satisfactory in predicting the membrane defect size. In this study, this integrity test method had about 39.33% probability to have a theoretic resolution of 3 μm or less under common experimental conditions.
Journal: Desalination - Volume 353, 17 November 2014, Pages 21–29