کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
625062 1455416 2011 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Response surface methodology for optimization of simultaneous COD, NH4+-N and Mn2+ removal from drinking water by biological aerated filter
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی تصفیه و جداسازی
پیش نمایش صفحه اول مقاله
Response surface methodology for optimization of simultaneous COD, NH4+-N and Mn2+ removal from drinking water by biological aerated filter
چکیده انگلیسی
This study investigated the effectiveness of a biological aerated filter (BAF) as an additional treatment in drinking water treatment plant systems for simultaneous chemical oxygen demand (COD), ammonium (NH4+-N) and manganese (Mn2+) removal. The experimental design was face centered-central composite design (FC-CCD) with three operational variables: COD load, aeration rate (AR) and hydraulic retention time (HRT). Optimum conditions for maximum COD, NH4+-N and Mn2+ removal were determined through response surface methodology, where COD load was set as the maximum while aeration rate and hydraulic retention time were minimized. The optimum conditions were found to be COD load of 0.90 kg/m3, AR of 0.30 L/min and HRT of 7.47 h with predicted simultaneous COD, NH4+-N and Mn2+ removal as 95.5%, 93.9% and 94.8%, respectively. These optimum conditions were used to estimate investment and operating cost of BAF system for a treatment capacity of 100,000 m3/day. The total capital and operating costs were estimated to be US$ 8,110,600 and US$ 0.022 per m3, respectively.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Desalination - Volume 275, Issues 1–3, 15 July 2011, Pages 50-61
نویسندگان
, , , ,