کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6252442 1612203 2016 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Original scientific articleCutting Edge in Thyroid Surgery: Autofluorescence of Parathyroid Glands
ترجمه فارسی عنوان
مقاله علمی مقاله لبه چسبندگی در عمل جراحی تیروئید: اتوفلورسانس غدد پاراتیروئید
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی عمل جراحی
چکیده انگلیسی

BackgroundIdentification of parathyroid glands may be challenging during thyroid and parathyroid surgery. Accidental resection of the glands may increase the morbidity of the surgery. The aim of this study was to evaluate accuracy in identification of autofluorescent parathyroid glands with the use of near infrared light in real time.Study DesignPatients undergoing thyroid and parathyroid surgery between June and August 2015 were included in the study. During the procedure, the surgical field was exposed to near infrared laser light in order to analyze the intensity of the fluorescence of different tissues (parathyroid glands, thyroid glands, and background). Surgical images were recorded and analyzed.ResultsTwenty-eight patients were included in the study. Nineteen patients were women and 9 were men. Seven patients had primary hyperparathyroidism, 4 had hyperthyroidism, 3 had goiters, and 11 had thyroid cancer. Three patients had mixed pathologies, including 2 patients with thyroid cancer and primary hyperparathyroidism and 1 patient with goiter and primary hyperparathyroidism. Identification of autofluorescent parathyroid glands was achieved in all patients with near infrared light.The mean fluorescent intensity of parathyroid glands was 40.6 (±26.5), thyroid glands 31.8 (±22.3), and background 16.6 (±15.4). Parathyroid glands demonstrated statistically higher fluorescence intensity compared with the thyroid gland and background (p < 0.0014). No postoperative hypocalcemia or other complications related to the surgery were registered.ConclusionsVisualization of autofluorescent parathyroid glands with the use of near infrared light allows high rates of parathyroid gland identification and could be a safe, feasible, and noninvasive method for intraoperative identification of parathyroid glands in real time. Further clinical studies must be performed to determine the cost-effectiveness and clinical application of this method.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Surgeons - Volume 223, Issue 2, August 2016, Pages 374-380
نویسندگان
, , , , , , ,